User's Guide
Extech EX830 True RMS 1000 Amp
Clamp Meter with IR Thermometer
Przeglądanie stron 0
1 2 3 4 5 6 ... 11 12

Podsumowanie treści

Strona 1 - User's Guide

User's Guide Extech EX830 True RMS 1000 Amp Clamp Meter with IR Thermometer

Strona 2 - Introduction

EX830-EU-EN v5.4 11/13 10Maintenance WARNING: To avoid electrical shock, disconnect the meter from any circuit, remove the test leads from the input

Strona 3 - CAUTIONS

EX830-EU-EN v5.4 11/13 11Specifications Function Range & Resolution Accuracy (% of reading + digits) AC Current 50/60 Hz 400.0 AAC ± (2.5% +

Strona 4 - Description

EX830-EU-EN v5.4 11/13 12 Function Range and Resolution Accuracy (% of reading + digits) Temperature (type-K) -4 to 1400oF ± (3%rdg + 9oF) -20 t

Strona 5 - Operation

EX830-EU-EN v5.4 11/13 2 Introduction Congratulations on your purchase of the Extech EX830 True RMS 1000A Clamp Meter. This meter measures AC/DC Vol

Strona 6 - Resistance Measurements

EX830-EU-EN v5.4 11/13 3 CAUTIONS  Improper use of this meter can cause damage, shock, injury or death. Read and understand this user manual befor

Strona 7 - ) position

EX830-EU-EN v5.4 11/13 4 Description Meter Description 1. Current clamp 2. Clamp opening trigger 3. Data Hold Button 4. Mode 5. Peak 6. Range 7.

Strona 8

EX830-EU-EN v5.4 11/13 5 Operation NOTES: Read and understand all Warning and Caution statements in this operation manual prior to using this meter.

Strona 9 - Units Switch

EX830-EU-EN v5.4 11/13 6 Resistance Measurements Note: Remove power before making resistance measurements 1. Insert the black test lead into the ne

Strona 10 - Maintenance

EX830-EU-EN v5.4 11/13 7 Type K Temperature Measurements 1. Set the function switch to the K Temp position. 2. Insert the Temperature Probe into

Strona 11 - Specifications

EX830-EU-EN v5.4 11/13 8 Non-Contact InfraRed Temperature Measurements 1. Set the function switch to the IR Temp position. 2. Aim the infrared sen

Strona 12 - ISO‐9001Certified

EX830-EU-EN v5.4 11/13 9 Data Hold To freeze the LCD reading, press the HOLD button. While data hold is active, the HOLD icon appears on the LCD. Pr