Extech Instruments MultiMaster MM560A Podręcznik Użytkownika

Przeglądaj online lub pobierz Podręcznik Użytkownika dla Multimetry Extech Instruments MultiMaster MM560A. Extech Instruments MultiMaster MM560A User`s guide Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 24
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
User’s Guide
MultiMaster™ Digital MultiMeter Series
With PC Interface
Models:
MM560A
MM570A
A
Przeglądanie stron 0
1 2 3 4 5 6 ... 23 24

Podsumowanie treści

Strona 1 -

User’s Guide MultiMaster™ Digital MultiMeter Series With PC Interface Models: MM560A MM570A A

Strona 2

10 MM560A-MM570A-EU-EN V1.1 8/12  Resistance, Continuity functions Press SELECT button momentarily t

Strona 3

11 MM560A-MM570A-EU-EN V1.1 8/12 Capacitance, Diode test function Press SELECT button momentarily

Strona 4

12 MM560A-MM570A-EU-EN V1.1 8/12 other readings indicate the diode is resistive or shorted (defective).

Strona 5

13 MM560A-MM570A-EU-EN V1.1 8/12 A, mA, A, and %4-20mA Current functions Insert the red test lead into t

Strona 6

14 MM560A-MM570A-EU-EN V1.1 8/12 PC-COMM computer interface capabilities The instrument equips with an op

Strona 7

15 MM560A-MM570A-EU-EN V1.1 8/12 Backlighted display Press the SELECT button for 1 second or more to turn

Strona 8

16 MM560A-MM570A-EU-EN V1.1 8/12 5) MAINTENANCE WARNING To avoid electrical shock, disconnect the meter

Strona 9

17 MM560A-MM570A-EU-EN V1.1 8/12 Battery and Fuse replacement Battery use: 9V alkaline battery NEDA1604

Strona 10

18 MM560A-MM570A-EU-EN V1.1 8/12 6) SPECIFICATIONS Display: 4-4/5 digits 50,000 counts. Selectable stab

Strona 11

19 MM560A-MM570A-EU-EN V1.1 8/12 Power Supply: Single Alkaline 9V battery; NEDA1604A, JIS6AM6 or

Strona 12 - V1.1 8/12

2 MM560A-MM570A-EU-EN V1.1 8/12 1) SAFETY This manual contains information and warnings that must be foll

Strona 13

20 MM560A-MM570A-EU-EN V1.1 8/12 Electrical Specifications Accuracy is (% reading digits + number of dig

Strona 14

21 MM560A-MM570A-EU-EN V1.1 8/12 AC & AC+DC Voltage RANGE MM570A MM560A Accuracy* 20Hz -- 45Hz 2

Strona 15

22 MM560A-MM570A-EU-EN V1.1 8/12 DC Current RANGE Accuracy Burden Voltage 500.00A 0.15%+20d 0.15mV/A 5

Strona 16

23 MM560A-MM570A-EU-EN V1.1 8/12 Thermocouple range & accuracy not included Hz Line Level Frequency

Strona 17

24 MM560A-MM570A-EU-EN V1.1 8/12 ISO-9001 Certified

Strona 18

3 MM560A-MM570A-EU-EN V1.1 8/12 WARNING To reduce the risk of fire or electric shock, do not expose this

Strona 19

4 MM560A-MM570A-EU-EN V1.1 8/12 3) PRODUCT DESCRIPTION Panel Illustration A1234567 1) 5-4/5 d

Strona 20

5 MM560A-MM570A-EU-EN V1.1 8/12 Average sensing RMS calibrated RMS (Root-Mean-Square) is the term use

Strona 21

6 MM560A-MM570A-EU-EN V1.1 8/12 cause digit rolling or offset in voltage measurements. This series has a

Strona 22

7 MM560A-MM570A-EU-EN V1.1 8/12 A A ADCVACVHz Note: Line Level Frequency measuring function input sen

Strona 23

8 MM560A-MM570A-EU-EN V1.1 8/12 Hz Logic Level Frequency and % Duty Cycle functions Press SELECT butto

Strona 24 - ISO-9001 Certified

9 MM560A-MM570A-EU-EN V1.1 8/12 T1-T2 Dual Channels Temperature function (MM570A only) Press SELECT butto

Komentarze do niniejszej Instrukcji

Brak uwag